CR005 LF EM4200 Reader Module

Description:


  • Numerus uber:CR005 LF EM4200 Reader Module
  • pluma productum:CR005 LF EM4200 Reader Module
  • Product Detail

    Product Tags

    Basic notitia

    Module 125khz EM4200 EM4100 , 12cm range
    CR005 est 125K lector modulus tantum EM4200 EM4100 TK4100 UART vel Weigand Modus quid habeat 3v vel 5v optionis ad samll magnitudinem et pretium humilis;

    CR005 SERIES Proximity Reader Module

    CR005 LF EM4200 Reader Module005
    CR005 LF EM4200 Reader Module002
    CR005 LF EM4200 Reader Module003
    Legere dolor 8-12cm
    Dimensiones 19mm(L)x18mm(H)x9.8mm(W)
    Frequency 125kHz
    Forma card uEM (IV)I vel compatible
    modum translitterandi Manchester 64-bit, modulorum 64
    Potentia opus est 5VDC @ 35mA nominalem
    Voltage Supple Range +4.6V per +5.4VDC

    CR005L 3~3.3C

    Propinquitas Lector Modules
    Characteres operationales et corporales

    Pin E

    CR005 LF EM4200 Reader Module

    PinNo. Descriptio CR005T (ASCII) CR005W(Wiegand) CR005M CR005A(ABAⅡ)
    Pin 1A VCC CR005 4.5~5.5 V

    CR005L 2.8~3.6V

    Pin 2A RFU NC
    Pin 3A BUZZ Humilis cum mico card
    Pin 4A RXD Wg0
    Pin 5A TXD Wg1
    Pin 6A Sle1 RFU
    Pin 1B Sle2 RfU Wg D0
    Pin 2B Ant0 1000uh Coil
    Pin 3B Ant1 Wg D1
    Pin 4B
    Pin 5B GnD

    CR005W01 = Wiegand26
    CR005W02 = Wiegand26/34 Switch
    CR005W03 = Wiegand34

    Data Formata

    CR005T-01Output Data Structure- ASCII(RS232.TTL) 9600bps,N,8,1
    [Ascii 1byte (2 charatres), LCR est Redundantia longitudinalis perscriptio.
    Exempli gratia:DATA : 62H E3H 08H 6CH EDH, LRC : (62H) XOR (E3H) XOR (08H) XOR (6CH) XOR (EDH)=08H, Output: 0X02 0X36 0X32 0X45 0X33 0X30 0X38 0X36 0X43 0X45 0X44 0X30 0X38 0X43

    CR005T-02Output Data Structure- ASCII(RS232.TTL) 9600bps,N,8,1
    [Ascii 1byte (2 charatres), LCR est Redundantia longitudinalis perscriptio.
    Exempli gratia:DATA : 62H E3H 08H 6CH EDH, LRC : (62H) XOR (E3H) XOR (08H) XOR (6CH) XOR (EDH)=08H, Output: 0X02 0X36 0X32 0X45 0X33 0X30 0X38 0X36 0X43 0X45 0X44 0X08 0X03

    CR005T-03Output Data Structure- ASCII(RS232.TTL) 9600bps,N,8,1
    [Ascii 1byte (2 charatres), LCR est Redundantia longitudinalis perscriptio.
    Exempli gratia:DATA : 62H E3H 08H 6CH EDH,
    Output: 0X36 0X32 0X45 0X33 0X30 0X38 0X36 0X43 0X45 0X44 0X0D

    CR005W Output Data Structure, Pro Exemplum: Wiegand 26 bit

    1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
    P (1) E E E E E E E E E E E E O O O O O O O O O O O O P (2)
    Par (E) ODD Par (o)

    P (1): Paritas Committitur Bit, 2-13 frenum PAR vel paritas
    P(2): Paritas Siste Bit, 14-26 frenum ODD Paritas bit

    Weigand

    CR005 LF EM4200 Reader Module__001

    Data forma

    CR005 LF EM4200 Reader Module__002

    NOTA

    I: MSB mittere primum
    2: MSB primum 12Bits a vel frenum LSB 12 Bit ceptum frenum impar.

    NOTA

    I: MSB mittere primum
    2:MSB primum 12Bits est etiam frenum ceptum , LSB 12 Bit imparem frenum reprehendo.