CR003 LF EM4200 EM4100 TK4100 4100D UART WG26/WG34 modulus lectoris 3V vel 5V

Descriptio Brevis:

Numerus producti:CR003 LF EM4200 EM4100 TK4100 4100D UART WG26/WG34 Modulus Lectoris 3V vel 5V
proprietas producti:Modulus Lectoris LF CR003
EM4200 EM4100 TK4100 4100D UART WG26/WG34 Modulus Lectoris 3V vel 5V


Detalia Producti

Etiquettae Productarum

Informationes Fundamentales

Modulus Lectoris RFID LF 25kHz EM4200 EM4100 TK4100 UART / Modus Weigand

CR003 est modulus lectoris tantum 125K EM4200 EM4100 TK4100 UART vel Weigand Mode, qui versionem 3v vel 5v habet et magnitudinem DIP28 habet.

CR003 LF EM4200 EM4100 TK4100 4100D UART WG26_002
CR003 LF EM4200 EM4100 TK4100 4100D UART WG26_003
CR003 LF EM4200 EM4100 TK4100 4100D UART WG26_004

Proprietates Operationales et Physicae

Nomen Modulus Lectoris Proximitatis seriei CR003
Pondus 12g
Dimensiones 40mm (L) × 20mm (A) × 8mm (L)
Temperatura -40一s+85C
Interfacies COMS UART vel WG
Spatium Lectionis usque ad 8~12 cm
Frequentia 125KHz
Aptus pro uEM 4001 vel compatibilis
EM4200, EM4100, TK4100, HT4168, 4100D
Potentia Requisita DC3.0-5.5V, 30mA-50mA
MCU CPU 51-8-bit

Descriptio Aciculorum et Formae Datorum Exitus

Numerus Clavi Descriptio CR003T (ASCII) CR003W (Wiegand) CR003M CR003A(ABAII)
Acus 1 D1 Emissio Datorum TTL (Tx) Egressus DATA1 Data OutputManchester Code Emissio DATARUM
Clavus 2 D0 NC Egressus DATA0 NC CLK
Clavus 3 CS NC NC NC CP
Clavus 4 Terra Terra
Clavus 5 VCC POTENTIA (+4.6V - +5.4V DC)
Clavus XV ANT1 Ad Antennam (L1 = 1000uH)
Clavus XVI ANT2 Ad Antennam
Clavus XXVI Terra Terra
Clavus XXVII VCC POTENTIA (+4.6V - +5.4VDC)
Clavus XXVIII SONUS/LED SONUS/LED SONUS/LED NC SONUS/LED

* Pin28 est moderator PEEPER/LED; post emissionem datorum, Pin28 humilis gradus ponitur.
CR003W01 = Wiegand26
CR003W02 = Wiegand26/34 Commutator
CR003W03 = Wiegand34

Formata Datorum

CR003T-01Structura Datorum Egressus – ASCII (RS232.TTL) 9600bps, N, 8, 1

STX (02H) DATA(10 ASCII) LRC (2 ASCII) CR LF
ETX (03H)

[Unum octetum (duo characteres ASCII), LCR est Longitudinalis Redundantiae Examen.]

Exempli gratia:DATA: 62H E3H 08H 6CH EDH, LRC: (62H) XOR (E3H) XOR (08H) XOR (6CH) XOR (EDH) = 08H, Egressus: 0X02 0X36 0X32 0X45 0X33 0X30 0X38 0X36 0X43 0X45 0X44 0X30 0X38 0X0D 0X0A 0X03

CR003T-02Structura Datorum Egressus – ASCII (RS232.TTL) 9600bps, N, 8, 1

STX (02H) DATA(10 ASCII) LRC (1BYTEI) ETX (03H)

[Unum octetum (duo characteres ASCII), LCR est Longitudinalis Redundantiae Examen.]

Exempli gratia:DATA: 62H E3H 08H 6CH EDH, LRC: (62H) XOR (E3H) XOR (08H) XOR (6CH) XOR (EDH) = 08H, Exitus: 0X02 0X36 0X32 0X45 0X33 0X30 0X38 0X36 0X43 0X45 0X44 0X08 0X03

CR003T-03Structura Datorum Egressus – ASCII (RS232.TTL) 9600bps, N, 8, 1

DATA(10 ASCII) CR

[Unum octetum (duo characteres ASCII), LCR est Longitudinalis Redundantiae Examen.]

Exempli gratia:DATA: 62H E3H 08H 6CH EDH
Exitus: 0X36 0X32 0X45 0X33 0X30 0X38 0X36 0X43 0X45 0X44 0X0D

CR003WStructura Datorum Egressus, Exempli gratia: Wiegand 26 bit

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
P(1) E E E E E E E E E E E E O O O O O O O O O O O O P(2)
Paritas PAR (E) Paritas Impar (O)

P(1): Bitus Initii Paritatis, bitus paritatis 2-13 bitorum paris
P(2): Bitum Sistendi Paritatis, bitum paritatis ODD 14-26 bitorum

Weigand

R003 LF EM4200 EM4100 TK4100 4100D UART WG263

Forma datorum:

R003 LF EM4200 EM4100 TK4100 4100D UART WG261

Schema Circuitus pro Modulo CR003

R003 LF EM4200 EM4100 TK4100 4100D UART WG262


  • Praecedens:
  • Deinde:

  • Nuntium tuum hic scribe et nobis mitte.